Hardware Specifications                                        LED Indicators
                                                               •	Per Unit: Power 1, 2
Technology                                                     •	Per 10/100TX Port: Link/Activity, Full-duplex
                                                               •	Line Speed: 100/80/60/40/20Mbps and Link below 20Mbps
      Standards
       •	IEEE802.3 10BASE-T                                    Speed / Distance Reference
       •	IEEE802.3u 100BASE-TX
       •	IEEE802.3x full duplex and flow control               Distance (m)  Data rate (Mbps)
      Processing Type
       •	Half-duplex back-pressure and IEEE802.3x Full-duplex  300 100

         flow control                                          400 80
       •	Auto Negotiation
       •	Auto MDI/MDIX                                         600 60

Power                                                          800 40

      Input Voltage                                            ... ...
       •	12 to 48VDC (Terminal Block)
      Power Consumption                                        2600          1
       •	4.56W max. 0.38A @ 12VDC
                                                                     Note:
                        0.07A @ 48VDC                                 •	All speed selections are Symmetrical on the DSL and Full-
      Protection
       •	Over current protection                                        duplex on the Ethernet
       •	Reverse polarity protection                                  •	The data rate will vary according to line quality

Mechanical                                                     Environment

      Casing                                                         Operating Temperature
       •	Aluminum case                                                •	-40°C to 75°C (-40°F to 167°F)
       •	IP30
      Dimensions                                                        Tested @ -40°C to 85°C (-40°F to 185°F)
       •	42mm (W) x 90mm (D) x 100mm (H)                             Storage Temperature
                                                                      •	-40°C to 85°C (-40°F to 185°F)
         (1.65" (W) x 3.54" (D) x 3.94" (H))                         Ambient Relative Humidity
      Weight                                                          •	5% to 95% (non-condensing)
       •	0.41 Kg (0.9 lbs.)
      Installation                                             Regulatory Approvals
       •	DIN-Rail (Top hat type 35mm) mounting
                                                                     ISO
Interface                                                             •	Manufactured in an ISO9001 facility

      Ethernet Port                                                Safety
       •	Port: One RJ-45 port                                        UL60950-1, EN60950-1, IEC60950-1
       •	Speed: 10/100Mbps
       •	Distance: 100 meters (328ft.)                             EMI
       •	Cable: 10BASE-T: UTP CAT. 3, 4, 5 (2-pair wire)             FCC Part 15B, Class A
                                                                     VCCI, Class A
                 100BASE-TX: UTP CAT. 5 (4-pair wire)                EN61000-6-4
      Ethernet Extender Port
       •	Port: One RJ-11/Terminal Block port                       EMS
       •	Speed: Up to 100Mbps                                        EN61000-6-2
       •	Distance: 2600 meters (8,530 ft.)                            •	EN61000-4-2 (ESD Standards)
       •	Cable: Telephone wire 24 AWG                                 •	EN61000-4-3 (Radiated RFI Standards)
                                                                      •	EN61000-4-4 (Burst Standards)
         (0.5mm diameter, 1-pair wire) or larger                      •	EN61000-4-5 (Surge Standards)
      DIP-Switch                                                      •	EN61000-4-6 (Induced RFI Standards)
       •	DIP 1 Site: Auto/Loc                                         •	EN61000-4-8 (Magnetic Field Standards)
       •	DIP 2 LDR: ON/OFF
                                                                   Environmental Test Compliance
                                                                     IEC60068-2-6 Fc (Vibration Resistance)
                                                                     IEC60068-2-27 Ea (Shock)
                                                                     FED STD 101C Method 5007.1 (Free fall w/ package)

ED3541                                                         22 www.EtherWAN.com